Update climate.yaml to replace grid status conditions with powerwall grid status checks, ensuring HVAC operations are only triggered when the powerwall is active. Enhance powerwall.yaml with detailed comments on binary sensors, power and energy sensors, and switches for better clarity and documentation.

This commit is contained in:
Carlo Costanzo
2025-11-26 15:16:21 -05:00
parent bf972d7d73
commit 6615179da5
2 changed files with 42 additions and 14 deletions

View File

@@ -5,8 +5,36 @@
# Read more about this on https://www.vcloudinfo.com
# Tesla Powerwall added via UI Integration
# Tesla Powerwall Monitoring #272
######################################################################################################
######################################################################
# --------------------------------------------------------------
# Binary Sensors:
# - binary_sensor.powerwall_charging ............. battery_charging (on=charging)
# - binary_sensor.powerwall_connected_to_tesla ... connectivity (on=connected)
# - binary_sensor.powerwall_grid_services_active .. power (on=active)
# - binary_sensor.powerwall_grid_status .......... power (on=grid up)
# - binary_sensor.powerwall_status ............... power (on=system ok)
#
# Power & Energy Sensors:
# - sensor.powerwall_charge ...................... battery %, 0100
# - sensor.powerwall_backup_reserve .............. reserve %, 0100
# - sensor.powerwall_battery_power ............... kW (+discharge / -charge)
# - sensor.powerwall_load_power .................. kW house load
# - sensor.powerwall_site_power .................. kW (+export / -import)
# - sensor.powerwall_solar_power ................. kW solar production
#
# Lifetime kWh Meters:
# - sensor.powerwall_battery_export .............. kWh → grid/load
# - sensor.powerwall_battery_import .............. kWh ← battery charged
# - sensor.powerwall_load_export ................. kWh exported from loads
# - sensor.powerwall_load_import ................. kWh imported to loads
# - sensor.powerwall_site_export ................. kWh site → grid
# - sensor.powerwall_site_import ................. kWh site ← grid
# - sensor.powerwall_solar_export ................ kWh solar → site/battery/grid
# - sensor.powerwall_solar_import ................ kWh solar ← grid (rare)
#
# Switches:
# - switch.powerwall_off_grid_operation .......... island mode toggle
######################################################################
#-------------------------------------------
automation: