											2005-10-18 21:06:38 +00:00
										 |  |  | * The SMS application | 
					
						
							|  |  |  | --------------------- | 
					
						
							|  |  |  | SMS() is an application to handles calls to/from text message capable phones and  | 
					
						
							|  |  |  | message centres using ETSI ES 201 912 protocol 1 FSK messaging over analog calls. | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | Basically it allows sending and receiving of text messages over the PSTN. It is  | 
					
						
							|  |  |  | compatible with BT Text service in the UK and works on ISDN and PSTN lines. It is  | 
					
						
							| 
									
										
										
										
											2008-06-12 17:27:55 +00:00
										 |  |  | designed to connect to an ISDN or DAHDI interface directly and uses FSK so would  | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | probably not work over any sort of compressed link (like a VoIP call using GSM codec). | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | Typical applications include:- | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | 1. Connection to a message centre to send text messages - probably initiated via the  | 
					
						
							|  |  |  |    manager interface or "outgoing" directory | 
					
						
							|  |  |  | 2. Connection to an POTS line with an SMS capable phone to send messages - probably | 
					
						
							|  |  |  |    initiated via the manager interface or "outgoing" directory | 
					
						
							|  |  |  | 3. Acceptance of calls from the message centre (based on CLI) and storage of  | 
					
						
							|  |  |  |    received messages | 
					
						
							|  |  |  | 4. Acceptance of calls from a POTS line with an SMS capable phone and storage of | 
					
						
							|  |  |  |    received messages | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | * Arguments to sms(): | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | - First argument is queue name | 
					
						
							|  |  |  | - Second is options: | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  |  a: SMS() is to act as the answering side, and so send the initial FSK frame | 
					
						
							|  |  |  |  s: SMS() is to act as a service centre side rather than as terminal equipment | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | - If a third argument is specified, then SMS does not handle the call at all, | 
					
						
							|  |  |  |   but takes the third argument as a destination number to send an SMS to | 
					
						
							|  |  |  | - The forth argument onward is a message to be queued to the number in the | 
					
						
							|  |  |  |   third argument. All this does is create the file in the me-sc directory. | 
					
						
							|  |  |  |   If 's' is set then the number is the source | 
					
						
							|  |  |  |   address and the message placed in the sc-me directory. | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | All text messages are stored in /var/spool/asterisk/sms | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | A log is recorded in /var/log/asterisk/sms | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | There are two subdirectories called sc-me.<queuename> holding all | 
					
						
							|  |  |  | messages from service centre to phone, and me-sc.<queuename> holding all | 
					
						
							|  |  |  | messages from phone to service centre. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | In each directory are messages in files, one per file, using any filename not | 
					
						
							|  |  |  | starting with a dot. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When connected as a service centre, SMS(s) will send all messages waiting in | 
					
						
							|  |  |  | the sc-me-<queuename> directory, deleting the files as it goes. Any | 
					
						
							|  |  |  | received in this mode are placed in the me-sc-<queuename> directory. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When connected as a client, SMS() will send all messages waiting in the | 
					
						
							|  |  |  | me-sc-<queuename> directory, deleting the files as it goes. Any received in | 
					
						
							|  |  |  | this mode are placed in the sc-me-<queuename> directory. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Message files created by SMS() use a time stamp/reference based filename. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The format of the sms file is lines that have the form of key=value | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | Keys are : | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | oa	Originating Address | 
					
						
							|  |  |  | 	Telephone number, national number if just digits | 
					
						
							|  |  |  | 	Telephone number starting with + then digits for international | 
					
						
							|  |  |  | 	Ignored on sending messages to service centre (CLI used) | 
					
						
							|  |  |  | da	Destination Address | 
					
						
							|  |  |  | 	Telephone number, national number if just digits | 
					
						
							|  |  |  | 	Telephone number starting with + then digits for international | 
					
						
							|  |  |  | scts	Service Centre Time Stamp | 
					
						
							|  |  |  | 	In the format YYYY-MM-DD HH:MM:SS | 
					
						
							|  |  |  | pid	Protocol Identifier (decimal octet value) | 
					
						
							|  |  |  | dcs	Data coding scheme (decimal octet value) | 
					
						
							|  |  |  | mr	Message reference (decimal octet value) | 
					
						
							|  |  |  | ud	The message (see escaping below) | 
					
						
							|  |  |  | srr	0/1 Status Report Request | 
					
						
							|  |  |  | rp	0/1 Return Path | 
					
						
							|  |  |  | vp	mins validity period | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Omitted fields have default values. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Note that there is special format for ud, ud# instead of ud= which is followed | 
					
						
							|  |  |  | by raw hex (2 characters per octet). This is used in output where characters | 
					
						
							|  |  |  | other than 10,13,32-126,128-255 are included in the data. In this case a comment (line | 
					
						
							|  |  |  | starting ;) is added showing the printable characters | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When generating files to send to a service centre, only da and ud need be | 
					
						
							|  |  |  | specified. oa is ignored. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | When generating files to send to a phone, only oa and ud need be specified. da is ignored. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2006-09-11 17:02:37 +00:00
										 |  |  | When receiving a message as a service centre, only the destination address is | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | sent, so the originating address is set to the callerid. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | EXAMPLES | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The following are examples of use within the UK using BT Text SMS/landline | 
					
						
							|  |  |  | service. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This is a context to use with a manager script. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | [smsdial] | 
					
						
							|  |  |  | ; create and send a text message, expects number+message and | 
					
						
							|  |  |  | ; connect to 17094009 | 
					
						
							|  |  |  | exten => _X.,1,SMS(${CALLERIDNUM},,${EXTEN},${CALLERIDNAME}) | 
					
						
							|  |  |  | exten => _X.,n,SMS(${CALLERIDNUM}) | 
					
						
							|  |  |  | exten => _X.,n,Hangup | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | The script sends | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | 	action: originate | 
					
						
							|  |  |  | 	callerid: message <from> | 
					
						
							|  |  |  | 	exten: to | 
					
						
							|  |  |  | 	channel: Local/17094009 | 
					
						
							|  |  |  | 	context: smsdial | 
					
						
							|  |  |  | 	priority: 1 | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | You put the message as the name of the caller ID (messy, I know), the | 
					
						
							|  |  |  | originating number and hence queue name as the number of the caller ID and the | 
					
						
							|  |  |  | exten as the number to which the sms is to be sent. The context uses SMS to | 
					
						
							| 
									
										
										
										
											2006-09-11 17:02:37 +00:00
										 |  |  | create the message in the queue and then SMS to communicate with 17094009 to | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | actually send the message. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Note that the 9 on the end of 17094009 is the sub address 9 meaning no sub | 
					
						
							|  |  |  | address (BT specific). If a different digit is used then that is the sub | 
					
						
							|  |  |  | address for the sending message source address (appended to the outgoing CLI | 
					
						
							|  |  |  | by BT). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | For incoming calls you can use a context like this :- | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | [incoming] | 
					
						
							| 
									
										
										
										
											2005-10-18 21:06:38 +00:00
										 |  |  | exten => _XXXXXX/_8005875290,1,SMS(${EXTEN:3},a) | 
					
						
							|  |  |  | exten => _XXXXXX/_8005875290,n,System(/usr/lib/asterisk/smsin ${EXTEN:3}) | 
					
						
							|  |  |  | exten => _XXXXXX/_80058752[0-8]0,1,SMS(${EXTEN:3}${CALLERIDNUM:8:1},a) | 
					
						
							|  |  |  | exten => _XXXXXX/_80058752[0-8]0,n,System(/usr/lib/asterisk/smsin ${EXTEN>:3}${CALLERIDNUM:8:1}) | 
					
						
							|  |  |  | exten => _XXXXXX/_80058752[0-8]0,n,Hangup | 
					
						
							| 
									
										
										
										
											2004-04-28 20:43:06 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | In this case the called number we get from BT is 6 digits (XXXXXX) and we are | 
					
						
							|  |  |  | using the last 3 digits as the queue name. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Priority 1 causes the SMS to be received and processed for the incoming call. | 
					
						
							|  |  |  | It is from 080058752X0. The two versions handle the queue name as 3 digits (no | 
					
						
							|  |  |  | sub address) or 4 digits (with sub address). In both cases, after the call a | 
					
						
							|  |  |  | script (smsin) is run - this is optional, but is useful to actually processed | 
					
						
							|  |  |  | the received queued SMS. In our case we email them based on the target number. | 
					
						
							|  |  |  | Priority 3 hangs up. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | If using the CAPI drivers they send the right CLI and so the _800... would be | 
					
						
							|  |  |  | _0800... | 
					
						
							|  |  |  | 
 |