Files
asterisk/res
Kinsey Moore b2c2a84e17 Ensure ReceiveFax provides a CED tone via T.38
When using res_fax_digium, the T.38 CED tone was not being provided
properly which would cause some incoming faxes to fail. This was not an
issue with res_fax_spandsp since it does not strictly honor the
send_ced flag and sends the CED tone whenever receiving a T.38 fax.

(closes issue FAX-343)
Reported-by: Benjamin Tietz
Patch-by: Kinsey Moore
........

Merged revisions 377655 from http://svn.asterisk.org/svn/asterisk/branches/1.8
........

Merged revisions 377656 from http://svn.asterisk.org/svn/asterisk/branches/10


git-svn-id: https://origsvn.digium.com/svn/asterisk/branches/11@377657 65c4cc65-6c06-0410-ace0-fbb531ad65f3
2012-12-10 16:55:05 +00:00
..
2012-06-15 16:20:16 +00:00
2012-06-25 15:55:25 +00:00
2012-05-18 14:43:44 +00:00