Added Temp Automations for the Garage. and took the smart switches from the garage out of the group so they won't be shut by acccident. Closes #1500

This commit is contained in:
CCOSTAN 2025-01-31 18:56:37 +00:00
parent f8f7e0cfcf
commit 0d95692dc9
2 changed files with 47 additions and 5 deletions

View File

@ -21,11 +21,6 @@ Interior Switches:
- switch.living_room_tv_outlet
- switch.office_lamp_switch_socket
- switch.front_office_lamp
- switch.smart_power_strip_socket_1
- switch.smart_power_strip_socket_2
- switch.smart_power_strip_socket_3
- switch.smart_power_strip_socket_4
- switch.smart_power_strip_usb_1
Kitchen Accents:
entities:

47
config/packages/glances.yaml Executable file
View File

@ -0,0 +1,47 @@
#-------------------------------------------
# Setting up Glances Integration for home assistant to track ProxMox stats
# @CCOSTAN
# Original Repo : https://github.com/CCOSTAN/Home-AssistantConfig
#
#-------------------------------------------
sensor:
- platform: template
sensors:
proxmox_garage_avg_temp:
friendly_name: "Proxmox Garage Average Temperature"
unit_of_measurement: "°F"
value_template: >-
{{ (
(states('sensor.proxmox1_package_id_0_temperature') | float(0) +
states('sensor.proxmox1_pch_skylake_1_temperature') | float(0) +
states('sensor.proxmox1_core_0_temperature') | float(0) +
states('sensor.proxmox1_core_1_temperature') | float(0) +
states('sensor.proxmox1_core_2_temperature') | float(0) +
states('sensor.proxmox1_core_3_temperature') | float(0) +
states('sensor.proxmox1_acpitz_1_temperature') | float(0) +
states('sensor.proxmox1_acpitz_2_temperature') | float(0) +
states('sensor.proxmox2_package_id_0_temperature') | float(0) +
states('sensor.proxmox2_pch_skylake_1_temperature') | float(0) +
states('sensor.proxmox2_core_0_temperature') | float(0) +
states('sensor.proxmox2_core_1_temperature') | float(0) +
states('sensor.proxmox2_core_2_temperature') | float(0) +
states('sensor.proxmox2_core_3_temperature') | float(0) +
states('sensor.proxmox2_acpitz_1_temperature') | float(0) +
states('sensor.proxmox2_acpitz_2_temperature') | float(0)
) / 16 ) | round(1) }}
automation:
- alias: "Garage Proxmox High Temperature Warning"
id: proxmox-garage-high-temp-warning-automation
trigger:
- platform: numeric_state
entity_id: sensor.proxmox_garage_avg_temp
above: 145 # Adjust threshold as needed
action:
- service: script.notify_engine
data:
title: "🔥 Proxmox Garage Alert!"
value1: "The average temperature of your Proxmox servers is above 90°F!"
who: 'carlo'
group: 'information'